ANSYS FLUENT 14.00 | ANSYS FLUENT 14.00 | ||
- | The convergence of each simulation was verified by the observation of three | + | The convergence of each simulation was verified by the observation of three generalised areas: |
a) The target residual values have been met. | a) The target residual values have been met. | ||
- | |||
- | |||
- | |||
- | Dr. Pooya | + | b) The overall domain imbalances are less than 1% (as recommended in ANSYS user manual). |
- | Ph.D. MEng | + | |
+ | c) Quantitative monitors (such as temperature and density differences) that have been placed, were no longer changing significantly (i.e. they have reached and maintained a static value). | ||
+ | |||
+ | Dr. Pooya Arjomandnia | ||
+ | Ph.D. MEng MIEAUST CPEng |
Latest revision as of 01:52, 29 December 2021
CFD Simulation of LNG Rollover ANSYS FLUENT 14.00
The convergence of each simulation was verified by the observation of three generalised areas:
a) The target residual values have been met.
b) The overall domain imbalances are less than 1% (as recommended in ANSYS user manual).
c) Quantitative monitors (such as temperature and density differences) that have been placed, were no longer changing significantly (i.e. they have reached and maintained a static value).